| Sign In | Join Free | My burrillandco.com |
|
Excellent unidirectional switches for phase control applications such as heating and motor speed controls. Standard phase control SCRs are triggered with few milliamperes of current at less than 1.5V potential.
Typical applications are AC solid-state switches, industrial power tools, exercise equipment, white goods and commercial appliances.
| Symbol | Parameter | Test Conditions | Value | Unit | Sxx55R | Sxx55N | Sxx55W | Sxx55M |
| IT(RMS) | RMS on-state current | TC = 90C | 55 | A | ||||
| VDRM/VRRM | Stand-off Voltage | 400 to 1000 | V | |||||
| IGT | Gate Trigger Current | VD = 12V; RL = 30 | MAX. 40 | mA | ||||
| ITSM | Peak non-repetitive surge current | single half cycle; f = 50Hz; TJ (initial) = 25C | 550 | A | ||||
| ITSM | Peak non-repetitive surge current | single half cycle; f = 60Hz; TJ (initial) = 25C | 650 | A | ||||
| I2t | I2t Value for fusing | tp = 8.3 ms | 1750 | A2s | ||||
| di/dt | Critical rate of rise of on-state current | f = 60Hz ; TJ = 125C | 175 | A/s | ||||
| IGM | Peak gate current | TJ = 125C PW = 10S | 4.0 | A | ||||
| PG(AV) | Average gate power dissipation | TJ = 125C | 0.8 | W | ||||
| Tstg | Storage temperature range | -40 to 150 | C | |||||
| TJ | Operating junction temperature range | -40 to 125 | C | |||||
| R(J-C) | Junction to case (AC) | C/W | 0.5 | 0.53 | 0.5 | 0.53 | ||
| R(J-A) | Junction to ambient | C/W | 40 | |||||
| VTM | On-state voltage | IT = 110A; tp = 380s MAX. | 1.8 | V | ||||
| IDRM / IRRM | Leakage Current | VDRM / VRRM TJ = 25C | 10 to 5000 | A | 400 600V | 800 V | 1000 V | |
| IDRM / IRRM | Leakage Current | VDRM / VRRM TJ = 100C | 100 to 5000 | A | 400 600V | 800V | 1000V | |
| IDRM / IRRM | Leakage Current | VDRM / VRRM TJ = 125C | 2000 to 5000 | A | 400 600V | 800V | 1000V | |
| VGT | Gate Trigger Voltage | VD = 12V; RL = 30 MAX. | 1.5 | V | ||||
| dv/dt | Critical rate of rise of off-state voltage | VD = VDRM; gate open; TJ = 100C | 250 to 650 | V/s | 400V | 600V | 800V | 1000V |
| dv/dt | Critical rate of rise of off-state voltage | VD = VDRM; gate open; TJ = 125C | 475 to 550 | V/s | 400V | 600V | 800V | |
| VGD | Gate Non-trigger Voltage | VD = VDRM; RL = 3.3 k; TJ = 125C MIN. | 0.2 | V | ||||
| IH | Holding Current | IT = 400mA (initial) MAX. | 60 | mA | ||||
| tq | Turn-off time | MAX. 35 | s | |||||
| tgt | Gate-controlled turn-on time | IG = 2 x IGT; PW = 15s; IT = 110A TYP. | 2.5 | s |
|